hOmeLabs HME021007N Commercial Grade Dehumidifier 160 Pint Built-In Pump

User Manual - Page 6

For HME021007N.

PDF File Manual, 16 pages, Read Online | Download pdf file

HME021007N photo
Loading ...
Loading ...
Loading ...
6 7
Installation
ACCESSORIES
2
3
1
4
5
6
8
4
5
6
7
9
10
10
PARTS NAME DIMENSIONS QUANTITY
1. Main Body
2. Handle
3. Screw 6 × 35 mm 4 pcs (2 spare)
4. Washer 13 × 24 × 3 mm 2 pcs (4 spare)
5. Wheel 2 pcs
6. Locating Pin 2 pcs
7. Caster 2 pcs
8. Screw 4 × 10 mm 8 pcs (4 spare)
9. Axle
10. Screw M6 × 25 mm 2 pcs (1 spare)
5. CHECKING FOR PRESENCE OF REFRIGERANT
The area shall be checked with an appropriate refrigerant detector prior to and during work,
to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak
detection equipmen
t being used is suitable for use with flammable refrigerants,
i.e. no sparking, adequately sealed or intrinsically safe.
6. PRESENCE OF FIRE EXTINGUISHER
If any hot work is to be conducted on the refrigeration equipment or any associated parts,
appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2
fire extinguisher adjacent to the charging area.
7. NO IGNITION SOURCES
No person carrying out work in relation to a refrigeration system which in
volves exposing
any pipe work that contains or has contained flammable refrigerant shall use any sources
of ignition in such a manner that it may lead to the risk of fire or explosion. All possible
ignition sources, including cigarette smoking, should be kept sufficiently far away from the
site of installation, repairing, removing and disposal, during which flammable refrigerant can
possibly be released to the surrounding space. Prior to work taking place, the area around the
equipment is to be surveyed to make sure that there are no flammable hazards or ignition
risks. “No Smoking” signs shall be displayed.
8. VENTILATED AREA
Ensure that the area is in the open or that it is adequately ventilated before breaking into the
system or conducting any hot work. A degree of ventilation shall continue during the period
that the work is carried out. The ventilation should safely disperse any released refrigerant
and preferably expel it externally into the atmosphere.
9. CHECKS TO
THE REFRIGERATION EQUIPMENT
Where electrical components are being changed, they shall be fit for the purpose and to the
correct specification. At all times the manufacturer’s maintenance and service guidelines shall
be followed. If in doubt consult the manufacturer’s technical department for assistance.
The following checks shall be applied to installations using flammable refrigerants:
• The charge size is in accordance with the room size within which the refrigerant containi
ng
parts are installed;
• The ventilation machinery and outlets are operating adequately and are not obstructed;
• If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for
the presence of refrigerant;
• Marking to the equipment continues to be visible and legible. Markings and signs that are
illegible shall be corrected;
• Refrigeration pipe or components are installed in a position where they are unlikely to be
exposed to any substance which may cor
rode refrigerant containing components, unless the
components are constructed of materials which are inherently resistant to being corroded or
are suitably protected against being so corroded.
10. CHECKS TO ELECTRICAL DEVICES
Repair and maintenance to electrical components shall include initial safety checks and
component inspection procedures. If a fault exists that could compromise safety, then no
electrical supply shall be connected to the circuit until it is satisfac
torily dealt with. If the
fault cannot be corrected immediately but it is necessary to continue operation, an adequate
temporary solution shall be used. This shall be reported to the owner of the equipment so all
parties are advised. Initial safety checks shall include:
• Those capacitors are discharged: this shall be done in a safe manner to avoid possibility
of sparking;
• That there no live electrical components and wiring are exposed while charging, recovering
or purging the system;
• That there is continuity of earth bonding.
WARNING:
Install the unit in rooms which exceed 4 m².Do not install the unit in a place where
inammable gas may leak.
NOTE: The manufacture may provide other suitable example or may provide additional
information about the refrigerant odour.
SAVE THESE INSTRUCTIONS