hOmeLabs HME021007N Commercial Grade Dehumidifier 160 Pint Built-In Pump

User Manual - Page 12

For HME021007N.

PDF File Manual, 16 pages, Read Online | Download pdf file

HME021007N photo
Loading ...
Loading ...
Loading ...
12 13
Clean the appliance exterior with
a soft wet cloth.
Clean the Filter
Pull the louver on the front panel
out to gain access to the Filter.
Remove the Filter.
Use a clean rag to absorb the surface dust
on the Filter. If the Filter is extremely dirty,
use potable tap water to flush it. Fully
dry the Filter before putting it into the Air
Inlet panel. A clean Filter will increase the
appliance’s efficiency.
Clean the Filter with potable water
at least once every 30 days.
Storage Requirements
If the unit will remain unused for an extended period of time, follow steps below:
Clean the Filter.
ATTENTION! The evaporator inside the appliance has to be dried out before the unit
is packed to avoid component damage. Unplug the unit and place it in a dry open
area for several days to dry it out.
Store the power cord on the Power Cord Hooks at the back of unit.
Cover the Dehumidifier with a plastic bag or a tarp.
Store the Dehumidifier upright in a dry, well-ventilated location.
Specifications
Voltage & Frequency AC 115 V, 60 Hz
Rated Capacity
45 Pints / Day @ 65°F, 60% RH
70 Pints / Day @ 80°F, 60% RH
120 Pints / Day @ 86°F, 80% RH
160 Pints / Day @ 95°F, 90% RH
Power Consumption & Current
532 W / 4.7 A @ 65°F, 60% RH
660 W / 5.8 A @ 80°F, 60% RH
780 W / 6.8 A @ 86°F, 80% RH
930 W / 8.1 A @ 95°F, 90% RH
Noise 60 dB(A)
Air Circulation 265 CFM
Refrigerant Type & Capacity R32 / 6.71 oz
Minimum Current of Power Supply 15 A
Maximum Design Pressure
High Side: 550 psig
Low Side: 260 psig
Compressor Input RLA: 5.5 A LRA: 27 A
Fan Motor Power 0.100 HP
Cleaning and Maintenance
Protection Codes
FL - The water full switch sensor failed or the Water Pump failed.
Operation
NOTE: When one of the above malfunctions occurs, turn off the Dehumidifier, and check
for any obstructions. Restart the Dehumidifier, if the malfunction is still present, turn off
the Dehumidifier and unplug the power cord. Contact Customer Service for repair
and/or replacement.