BEFORE YOU START (con’t)
BUILT-IN INSTALLATION
Lynx built-in accessories are intended for installation in a
built-in enclosure constructed of non-combustible materials.
The accessory drops into the opening shown in the cutout
detail drawing and hangs from its counter-top trim. A deck is
not required to support it from the bottom.
Pay special attention to the provisions shown for gas line
hook-up. (See INDEX: "Cut-out Dimensions for Built-in Grills
& Accessories")
Installation provisions may be made for the Power Burner
installation. The Power Burner cooking height may be
reduced to better accommodate large cooking pots.
Clearances to combustible material must be maintained
as outlined below. No combustible material shall be used
in the construction of a counter top using a recessed
application.
The enclosure should have ventilation holes to prevent gas
build-up in the event of a leak. The deck ledges and counter
should be fl at and level.
For an enclosure having four sides, a top and a bottom:
1. At least two ventilation openings shall be provided in the
side walls of the enclosure, located within 5 in (217 mm)
of the top of the enclosure, equally sized, placed on two
adjacent sides, and unobstructed. The opening(s) shall
have a total free area of not less than 10 square inches for
each 20lb cylinder tank stored.
2. Ventilation opening(s) shall be provided at fl oor level
of the enclosure and shall have a total free area of not
less than 10 square inches for each 20lb cylinder tank.
If ventilation openings at fl oor level are in a side wall,
there shall be at least two openings. The bottom of the
openings shall be 1 in (25.4 mm) or less from the fl oor
level and the upper edge no more than 5 in (127 mm)
above the fl oor level. The openings shall be equally
sized, placed on two adjacent sides and unobstructed.
3. Every opening shall have minimum dimensions so as to
permit the entrance of a 1/8 in (3.2 mm) diameter rod.
CLEARANCE TO COMBUSTIBLE MATERIALS
Minimum clearance from the sides and back of the
accessory to adjacent combustible construction below the
countertop is 12" from the sides and back.
Degagement minimal entre /es parois laterales et l'arriere
de l'appariel et la construction combustible au-dessous du
panneau superieur de l'appareil (30 cm a partir des parois
laterales et 30 cm a partir de l'arriere).
Minimum clearance from sides and back of unit to adjacent
combustible construction extending above the counter top
is 18" from the sides and back.
Degagement horizontal minimal entre /es parois laterales
et l'arriere de l'appariel et la construction verticale
combustible au-dessus de l'appareil (45.7 cm a partir des
parois laterales et 45.7 cm a partir de l'arriere).
Do not use this appliance under unprotected overhead
combustible surfaces.
Ne pas utiliser cet appareil sous une surface combustible
non protegee.