10
GAS CONNECTIONS
GAS PLUMBING
WARNING
Never connect a gas line directly to the accessory. A pressure regulator must be installed on all gas equipment.
The gas line can be teed o the regulator from the gas grill. If the accessory is not teed o the grill, it will require a
regulator. Removing or failing to install the pressure regulator can result in fi re and serious personal injury and will
void the warranty.
The accessory is factory set to use either propane (LP)
or natural gas (NAT). It is critical that the gas you use
matches that which the accessory was set up for. You can
verify that by checking the rating plate.
LYNX GRILLS, LLC
Greenwood, Mississippi 38930
THIS DESIGN CERTIFIED UNDER ANSI Z21.58; CSA 1.6 OUTDOOR COOKING GAS APPLIANCE
NAT. 4” (996 Pa) LP/PROP 10” WCP (2492 Pa)
The rating plate is located on the heat shield behind the
front panel.
Ensure that the gas supplied meets with the minimum
pressure requirements.
Do not operate the accessory on any gas other than that
for which the accessory has been set.
Fuel WC Max Inlet WC Min Under
Full Load
Nat Gas 7 in 4 in
LP 14 in 11 in
WATER COLUMN REQUIREMENTS
Both the regulator (LPB models only) and the manifold
orifi ces have been tuned for the type of gas specifi ed on
the rating plate.
Converting to a di erent type of gas requires a
conversion kit which is purchased separately and must be
installed by a qualifi ed technician.
All installation and all installation parts must conform to
local codes with the National Electrical Code, ANSI/NFPA
70-1990 and the National Fuel Gas Code, ANSI Z223.1 /
NFPA 54 in the U.S. and CGA-B149.1/.2 in Canada.
Canadian installations must conform to CGA-B149.1/.2
natural gas/propane installation code. (Canada)
NATURAL GAS
Lynx recommends that only qualifi ed professionals
perform the required plumbing on this product.
The gas supply line must be sized to accommodate the
total BTU requirements of all the gas-fi red equipment
that will be connected to that line.
Everything after the shut o valve has to be ½” inside
diameter. Before the shut o valve is ¾” inside diameter
and might have to go to a bigger gas line, depending on
the length of the gas installation and BTU’s needed.
Calculate the total BTU output of all equipment and
refer to the maximum runs for appliances. Failure to
meet these requirements may reduce performance of
the accessory and any other appliances running on
that supply line.
Always keep supply line runs as short as possible.
Refer to the maximum runs for appliances
A gas shut-o valve must be installed in an easily
accessible location by a qualifi ed plumber.
Keep any threading compound o of the fi rst two pipe
threads to avoid having any small pieces of compound
break loose and clog a burner valve or orifi ce. Do not
put sealant on any male end of fl are fi ttings.
Keep last two
threads clean
For built-in installations, it is recommended that any
exible pipe used be kept as short as possible.