Toyotomi IZURU TRN/TRG-835ZR

User Manual - Page 33

For IZURU TRN/TRG-835ZR.

PDF File Manual, 149 pages, Read Online | Download pdf file

IZURU TRN/TRG-835ZR photo
Loading ...
Loading ...
Loading ...
GB
33
Tools for installation
1. Level meter 2. Screw driver 3. Impact drill
4. Drill head 5. Pipe expander 6. Torque wrench
7. Open-end wrench 8. Pipe cutter 9. Leakage detector
10. Vacuum pump 11. Pressure meter 12. Universal meter
13. Inner hexagon spanner 14. Measuring tape
NOTE:
Please contact the local agent for installation.
Don’t use unqualified power cord.
Selection of installation location
BASIC REQUIREMENT
Installing the unit in the following places may
cause malfunction. If it is unavoidable, please
consult the local dealer:
1. The place with strong heat sources, vapors,
flammable or explosive gas, or volatile
objects spread in the air.
2. The place with high-frequency devices (such
as welding machine, medical equipment).
3. The place near coast area.
4. The place with oil or fumes in the air.
5. The place with sulfureted gas.
6. Other places with special circumstances.
7. The appliance shall not be installed in the
laundry.
INDOOR UNIT
1. There should be no obstruction near air inlet
a and air outlet.
2. Select a location where the condensation
water can be dispersed easily and won’t
affect other people.
3. Select a location which is convenient to
connect the outdoor unit and near the
power socket.
4. Select a location which is out of reach
for children.
5. The location should be able to with stand the
weight of indoor unit and won’t increase
noise and vibration.
6. The appliance must be installed 2.5m
above floor.
7. Don’t install the indoor unit right above the
electric appliance.
8. Please try your best to keep way from
fluorescent lamp.
OUTDOOR UNIT
1. Select a location where the noise and outflow air emitted by the outdoor unit will not
affect neighborhood.
2. The location should be well ventilated and dry, in which the outdoor unit won’t be exposed
directly to sunlight or strong wind.
3. The location should be able to withstand the weight of outdoor unit.
4. Make sure that the installation follows the requirement of installation dimension diagram.
5. Select a location which is out of reach for children and far away from animals or plants.
If it is unavoidable, please add the fence for safety purpose.
Loading ...
Loading ...
Loading ...