SERVICING - WARNING
Disconnect from electricity and gas before servicing. Check appliance is safe when you have nished.
9
Gently move the fan assembly away from the
appliance. The electrical connection between
the Fan assembly and the Appliance will become
visible. Disconnect the electrical connection and
move the fan assembly away.
The cooling fan is held into the metal cover by (x3)
securing screws.
Remove the (x3) screws and replace the cooling
fan.
b. Re- Assembly: Reassemble in the reverse order,
making sure all electrical connections broken are
returned to their normal operating state. Please refer
to the wiring diagram as required.
c. Check the electrical safety of the appliance by
carrying out the appropriate electrical safety
checks, earth bond and high Voltage Hi Pot tests.
8. Remove the Wire Covers x 3
Disconnect the appliance from the electricity Supply
Disconnect from the Gas Supply – Remove any
Safety Chains that may be present.
a. The appliance has (x2) wire covers and a mains
terminal cover (x1)
Wire Cover LH Rear Wire Cover RH Rear
Terminal Cover
b. Remove the Right Hand Rear Cover rst, locate and
remove the (x4) securing screws.
c. Remove the Terminal Cover, locate and remove the
(x2) securing screws.
d. Remove the Left Hand Wire Cover, locate and remove
the (x5) securing screws.
e. You now have access to the following :
Fan Element
Terminal Block
Bottom Element
Stirring Fan
Stirring Fan
Fan Element
Left Hand Oven
Top Elements
Broiler Element
Broiler Element
Terminal Box Area
Heating Elements
Circulation Fans
Thermostat Phials
f. Re- Assembly: Reassemble in the reverse order, take
care to ensure all wires situated on the rear of the
appliance are clear of the wire covers.
g. Check the electrical safety of the appliance by
carrying out the appropriate electrical safety
checks, earth bond and high Voltage Hi Pot tests.