Afilter-regulator-lubricatorsystemisrequiredandshouldbe
locatedasclosetotoolaspossible(seeFigure1,page3).
Adistanceoflessthan15feetisrecommended.
Keepairfilterclean.Adirtyfilterwillreducetheairpressure
tothetoolcausingareductioninpowerandefficiency.
Theairsupplysystemmustbeabletoprovideairpressure
of70to110poundspersquareinchattool.
Differentworkpiecematerialsanddifferentfastenerlengths
willrequiredifferentoperatingpressure.
Besureallconnectionsinairsupplysystemaresealedto
preventairloss.
Neverconnectafemalequick-connectcouplingtothetool
sideofairlineconnection.Amale,free-flowcoupling
shouldbeconnectedtothetoolsideofair.
Allhosesandpipesintheairsupplysystemmustbeclean
andfreeofmoistureandforeignparticles.
Donotmountswivelconnectorinairsupplyline.
Theairpressureshouldbeproperlyregulated.
WARNING:Thefemalecouplingprovidesasealpreventing
lossofcompressedairfromcompressortankwhendiscon-
nectedfrommalecoupling.Ifconnectedtotoolsideofairsup-
ply,thefemalecouplingcouldsealacompressedairchargein
thetoolwhichcoulddischargeifthetooltriggerisactuated.
2FootHoseWhip_
u- MaleQuick-Connect
Filter-Regulator-Lubricator--
\
Female Connect
Figure 1 - Air Supply Line
LOADING
Refer to Figures 2 & 7 (pages 3 and 8).
WARNING: Disconnect tool from air supply. Always load with
nose of tool pointing away from you and others. Always wear
safety goggles that comply with United States ANSI Z87.1.
NOTE: For best results, use Sears fasteners only.
Slide pusher (Figure 7, No. 68) towards rear of tool until it
locks into position.
Insert nails into opening at rear of magazine.
Hold pusher housing firmly and release by depressing
latch (Figure 7, No. 64). Allow pusher to gently slide for-
ward against nails.
NAILING OPERATION
Refer to Figures 3 & 7 (pages 3 and 8)
WARNING: Never operate tool unless contact trip is in con-
tact with workpiece. Do not operate tool without fasteners or
damage to tool may result. Never fire fasteners into the air
because fasteners may injure operator or others and damage
to tool may result.
* The air tool is equipped with a contact trip safety mecha-
nism (see Figure 3, page 3) that disables tool unless con-
tact trip is pushed against work. Hold body firmly and
press contact trip on workpiece where fastener is to be
applied. Pull trigger to drive fastener into workpiece.
Depress
Trigger
Trigger
Depressed
Figure 2 - Loading Nails
Figure 3 - Contact Trip Operation