Installation
*INSTALLATION*
55
When installing a condensate trap,
ensure that it is positioned vertically
and as closely as possible to the
ventilation hood above the exhaust
vent. The arrow on the casing indicates
the direction of airflow.
Miele will not accept warranty claims
for any functional defects or damage
caused by inadequate ducting.
Reducing Collar
(optional accessory)
If you would like to reduce the
environmental impact of your ventilation
system by limiting the CFM output the
Reducing Collar can be installed. It
reduces the air flow to less than
400CFM. Check local building codes
for max. CFM requirements.
Push the Reducing Collar on the
exhaust port of the blower.
Push the exhaust hose over it.
Secure both with a hose clamp.
Electrical connection
WARNING: TO REDUCE THE RISK
OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
All electrical work should be
performed by a qualified electrician
in strict accordance with national
regulations (for USA: ANSI-NFPA 70)
and local safety regulations.
Installation, repairs and other work
by unqualified persons could be
dangerous.
Ensure that power to the appliance is
OFF while installation or repair work
is performed.
Verify that the voltage, load and
circuit rating information found on
the data plate (located behind the
baffle filters), match the household
electrical supply before installing the
hood.
Use only with ventilation hood cord-
connection kits that have been
investigated and found acceptable
for use with this model hood.
If there is any question concerning
the electrical connection of this
appliance to your power supply,
please consult a licensed electrician
or call Miele’s Technical Service
Department.
WARNING: THIS APPLIANCE MUST
BE GROUNDED