Installation
*INSTALLATION*
41
f
A power cord is required to connect the hood to the socket in the ceiling. With
extraction mode flexible ducting is also required.
Exhaust connection 6" (150mm)
Distance between cooktop and ventilation hood (S)
Provided a larger distance is not given by the manufacturer of the cooktop,
follow the minimum safety distances between a cooktop and the bottom of the
hood.
Please also observe the information contained in the “IMPORTANT SAFETY
INSTRUCTIONS” section.
Minimum distance S
Cooking appliance Miele
appliance
Non-Miele
appliance
Electric Cooktops 24" (610mm)
Electric Barbeques and Fryers 26" (660mm)
Multiburner Gas Cooktops
43,000 BTU/hr (12.6kW),
no burner > 15,000 BTU/hr (4.5 kW).
26" (660mm) 30" (760mm)
Multiburner Gas Cooktops
73,800 BTU/hr (21.6kW),
no burner > 16,500 BTU/hr (4.8 kW)
30" (760mm)
Multiburner Gas Cooktops
> 73,800 BTU/hr (21.6kW),
or one of the burners > 16,500 BTU/hr (4.8 kW)
Not possible
Single Burner Gas Cooktops
20,500 BTU/hr (6 kW)
26" (660mm) 30" (760mm)
Single Burner Gas Cooktops
> 20,500 BTU/hr (6 kW)
27,600 BTU/hr (8.1 kW)
30" (760mm)
Single Burner Gas Cooktops
> 27,600 BTU/hr (8.1 kW)
Not possible