Operation (Automatic and Manual modes)
31
Filter saturation indicator
The ventilation hood registers the length
of time it has been operated.
The filter saturation indicators show
when the filters need to be cleaned or
changed by lighting up the grease filter
symbol or charcoal filter symbol .
Additional information on cleaning and
changing the filters and resetting the
filter saturation indicators can be found
under “Cleaning and care”.
Adjusting the grease filter filter
saturation indicator
The filter saturation indicator can be set
to suit the customer’s cooking habits.
The factory default setting is a cleaning
interval of 30hours.
- Select a shorter interval of 20hours if
food is fried regularly.
- A shorter cleaning interval is also
recommended if the customer only
cooks occasionally. This will prevent
grease buildup from hardening and
making cleaning more difficult.
- Select a longer cleaning interval of 40
or 50hours if the customer uses very
little fat when cooking.
Switch off the blower and the lighting.
Touch the delayed shutdown
control and the grease filter
control at the same time.
The grease filter symbol and one of
the blower power level indicators will
flash.
The indicators 1 to B show the current
time setting:
1............................................... 20hours
2............................................... 30hours
3............................................... 40hours
B .............................................. 50hours
Touch the relevant control to select
the duration required.
Confirm your choice by touching the
grease filter control .
All the indicator lights will go out.
If the new setting is not confirmed
within 4minutes, the ventilation hood
will revert to the previous setting.