Installation instructions
ELECTRICAL REQUIREMENTS
Read these instructions completely
and carefully.
CIRCUIT - Individual, properly polarized and grotmded
IS-amp branch circuit fused with 15-amp time-delay fllse
or circuk breaker:
POWER SUPPLY - 2-wire, with ground, 120=v(It, single-
phase, 60-Hz, Alternating Current.
OUTLET RECEIVFACLE - Properly grotmded
3-prong receptacle to be located so the power supply cord
is accessible when the w_ksher is in an installed position.
Q
GROUNDING REQUIREMENTS
A WARNING: mp,opetto.new,ionof
equipment grounding conductor can result in a risk
of electrical shock. Check with a licensed electrician
if you are in doubt as to whether the appliance is
properly grounded.
1.
The washer MUST be grounded. In die event of
ma/flmcfion or breakdown, gqounding will reduce
the risk of elecuicM shock by providing a path of least
resistance for electrical current.
2_
Since your w_ksher is equipped wifll a power supply
cord having an equipment%rounding conductor and
a grotmding plug, the plug MUST be plugged into an
appropfiam, coppe>wired receptacle that is properly
installed and gnounded in accordance with all locN
codes and ordinances or in the absence of locN codes,
with the NafionN Electrical Codes, ANSI/NFPA 70
(lamst edition). If in doubt, cN1 a licensed elecuician.
DO NOT cut off or Nmr the gTounding prong on the
power supply cord. In situations where a two.slot
receptacle is presenL it is the owner's responsibilky to
have a licensed elecuJdan replace it with a properly
grounded three-prong grounding-tTpe receptacle.
WATER SUPPLY REQUIREMENTS
Hot and cokt water fhucets MUST be installed within
42 inches (107 cm) of your washer's water inlet. The
fauce[s MUST be 3/4" (1.9 cm) garden hose-type so
inlet hoses can be connecmd. Wamr pressure MUST be
between 10 and 120 pounds pet square inch (maximmn
unbalanced pressure, hot vs. coM, 10 psi.) Your wamr
department can advise you of your water pressure.
The hot wamr mmperamre should be set to deliver
wamr at 120 ° to 140°F (48°-60°C).
DRAIN REQUIREMENTS
1. Drain capable of eliminating 17 ga/s (64.3 L)
pet minum.
2. A standpipe diamemr of 1 1/4" (3.18 cm) minimum.
3. The standpipe height above the floor
shouM be:
Minimum height: 24" (61l cm)
Maximum height: 96" (244 cm)
O
96 in.
(244 cm)
Max.
24 in.
(61 cm)
Min.
NOTE: The drain hose attached to file washer can reach
a 58" (147 cm) high standpipe. For a higher standpipe,
contact an authorized parts distributor If the drain is less
than 24" (61 cm), install a siphon break ldt, available at
your local hardware store.