26
- Australia:
- New Zealand:
- UK Only:
Category: II
2H3P.
Flue Type: A
1.
NOTE:
* - Measure burner operating pressure at gas control outlet test point with burner
operating at Highsetting.
Operating pressure is ex-factory set through appliance regulator and is not to be
adjusted, apart from when carrying out gas conversion, if required. (Refer to Gas
Conversionsection for details).
BP8080G / GE BP8120G / GE BP8080G / GE BP8120G / GE
Main Burner Injector Ø 4.30mm Ø 5.20mm Ø 2.50mm Ø 2.80mm
Pilot Burner Injector 0.35 0.20
Aeration Clearance (H) 30mm 30mm
Burner Operating Pressure (*) 0.76kPa 0.60kPa 2.5kPa 2.4kPa
Gas Regulator Cap Screw
BP8080G / GE BP8120G / GE BP8080G / GE BP8120G / GE
Main Burner Injector Ø 4.30mm Ø 5.20mm Ø 2.50mm Ø 2.80mm
Pilot Burner Injector 0.35 0.20
Aeration Clearance (H) 30mm 30mm
Supply Pressure 20mbar 37mbar
Burner Operating Pressure (*) 7.5mbar 6.0mbar 25.7mbar 25.5mbar
Gas Regulator Cap Screw
BP8080G / GE BP8120G / GE BP8080G / GE BP8120G / GE
Main Burner Injector Ø 4.30mm Ø 5.20mm Ø 2.50mm Ø 2.80mm
Pilot Burner Injector 0.35 0.20
Aeration Clearance (H) 30mm 30mm
Burner Operating Pressure (*) 0.76kPa 0.60kPa 2.5kPa 2.4kPa
Gas Regulator Cap Screw