2. Select CARDIOID.
The CARDIOID (REAR)… message appears.
3. Select YES.
The location is set to cardioid. For more information, see Subwoofer cardioid array, page
39.
LOW PASS Menu
The Low Pass menu is used to select low pass frequency for proper summation with a
full-range loudspeaker. Available options for this selection are: 80 Hz, 100 Hz, 120 Hz, 150 Hz,
ETX-10P, ETX-12P, ETX-15P and ETX-35P. The low passes are 24 dB/octave Linkwitz/Riley
slopes. The 80 Hz, 100 Hz, 120 Hz, and 150 Hz selections are generic low pass settings for use
with other full-range loudspeaker systems. The ETX-10P, ETX-12P, ETX-15P, and ETX-35P
settings are specifically optimized for ETX Powered Loudspeaker by including delay for best
summation.
The default is 100 Hz.
ROOM EQ
The Room EQ menu is a single-band EQ the user can fine tune beyond the function and
location. Available option for this selection is: PEQ1.
BACK
PEQ1: Default: 50 Hz
ETX-15SP Range: 35 Hz to 100 Hz
ETX-18SP Range: 30 Hz to 100 Hz
Default: 0 dB
Range: -12 dB to +6 dB
Q: 2.0
Notice!
The Room EQ range shown is the factory default settings on a stand alone subwoofer. Room
EQ low frequency range is dependant on the low pass setting selected.
DELAY Menu
The Delay menu is used to create time alignment with other subwoofers. Available options for
this selection are: NONE or a delay up to 343 m. The delay can be changed in 0.25 meter
increments. If the unit of measure is feet, available options for this selection are: NONE or a
delay up to 1125 ft. The delay can be changed in one (1) foot increments.
The default is NONE.