- Next using a flat screwdriver, gently pry out four cover bracket stubs from the side walls as shown
in Diagram 7.
- Then use pliers to straighten out the brackets neatly to a 90°angle. Refer to Diagrams 8 & 9.
- The recess box is now ready for installation.
2. Installing The Recess Box
- Fitting the Recess Box into a new construction masonry wall.
Bend out the 4 brick ties. Fit the recess box into the brickwork opening and anchor it to the masonry
by bending the brick ties to slot into the masonry joints and using mortar to secure. Check that
the box is level and allow ample time for the mortar to cure before fitting the water heater unit.
- Fitting the Recess Box into an existing wall.
Prepare an opening in the wall with a cavity size of : H-1015mm x W-390mm x D-158mm.
Place box into cavity and drill out holes at required fixture points and use appropriate fasteners
to secure firmly into position.
3. Mounting the Water Heater
- Once the recess box has been fitted onto the wall, mount the water heater in to the recess box by
following the instructions below.
-Carefully insert the water heater into the recess box and push upwards so that the water heater
upper mounting bracket goes into the 210mm x 8mm slot located at the top of the recess box.
Refer to Diagrams 11 - 13.
3
IMPORTANT! Ensure that the pipe inlet cutout is facing down when placing in position.