Specifications
- All Other Markets
NOTE:
 (*) Measure Burner operating pressure at manifold test point with two burners operating at
'High Flame' setting.
 NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted,
unless when converting between gases, if required.
 (**) TOWN GAS Only - Adjust burner operating pressure using adjustable gas regulator
supplied.
 Refer to ‘Gas Conversion and Specifications' section in this manual for further details.
Gas Connection
Gas supply connection point is located at rear of appliance, approximately 130mm from right hand
side, 32mm from rear and 655mm from floor (55mm from floor for bench top – B models) and is
reached from beneath appliance. (Refer to ‘Dimensions’ section).
Connection is ¾" BSP male thread (for all other models).
Natural Gas Town Gas (**)
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
28 MJ/hr
Supply Pressure
1.13 - 3.40 kPa 0.75 - 1.50 kPa
Burner Operating Pressure (*)
0.95 kPa 0.63 kPa
Gas Connection See ‘Gas Connection’ information below.
LP Gas / Butane
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
Supply Pressure
2.75 - 4.50 kPa
Burner Operating Pressure (*)
2.6 kPa
Gas Connection See ‘Gas Connection’ information below.