Waldorf RNLB8900G-LS Bold 900mm Gas Cooktop Low Back Version Leg Stand

Installation Operation Manual - Page 25

For RNLB8900G-LS.

PDF File Manual, 29 pages, Read Online | Download pdf file

RNLB8900G-LS photo
Loading ...
Loading ...
Loading ...
23
Gas Conversion and Specifications
Gas Specifications
- Australia
- New Zealand
- United Kingdom
Category: II
2H3P
(20, 37).
Flue Type: A
1.
NOTE: Measure burner operating pressure at manifold test point with two burners operating at full setting.
Operating pressure is ex-factory set, through appliance regulator and is not to be adjusted, apart from
when carrying out Gas Conversion, if required. (Refer to ‘Gas Conversion’ section for details).
Natural Gas (G20) Propane (G31)
Open Burner
Main Burner Injectors Ø 2.30mm Ø 1.40mm
Pilot Burner ('PF' Models only) 0.30 0.20
Supply Pressure 20 mbar 30 / 37 mbar
Burner Operating Pressure (*) 9.5 mbar 26 mbar
Gas Regulator Cap Screw
Natural. Gas LP Gas (Propane)
Open Burner
Main Burner Ø 2.45mm Ø 1.50mm
Pilot Burner ('PF' Models Only) 0.30 0.20
Supply Pressure 1.13 - 3-40 kPa 2.75 - 3-40 kPa
Burner Operating Pressure (*) 0.95 kPa 2.6 kPa
Gas Regulator Cap Screw
Natural. Gas LP Gas
Open Burner
Main Burner Ø 2.45mm Ø 1.40mm
Pilot Burner ('PF' Models Only) 0.30 0.20
Supply Pressure 1.13 - 3-40 kPa 2.75 - 3-40 kPa
Burner Operating Pressure (*) 0.95 kPa 2.6 kPa
Gas Regulator Cap Screw
Loading ...
Loading ...
Loading ...