CARE AND CLEANING OF YOUR WATER PURIFIER
continued from page 5
TO REPLACE CARBON FILTER (unit may be oper-
eted with or without the carbon fiitar).
1. Remove the lid fromthe carafe.
2. Remove the carbon compartment cover by puJl-
ing on tabs.
3. Remove the used carbon filter and discard. Do
not reuse carbon filter.
4. Rinse the inside of the carbon compartment with
water.
5. Remove carbon filter from plastic bag and dnse
under purified water for 30 seconds, so that it is
wet on all surfaces.
6. Put new carbon filter in carbon compartment. Be
sure carbon is evenly distributed within pouch.
7. Replace the carbon compartment cover and
place the carafe lid on the carafe.
8. Replace carafe onto the base unit.
9. On model 344810, be sure to reset the "Filter
Status Bar" by pressing and holding the delay
button for 7 seconds.
10. The next fime you make pudfied water, discard
the first batch of water which may have small,
harmloss, carbon fines in it.
carbon compartment cover
NOTE: The physiological effecLs of the operation of this appliance, beneficial or otherwise, have not been
investigated by Underwriters Laboratories. See Product Data Sheet for test data obtained from an independent
laboratory.
TROUBLESHOOTING CHECK LIST
NOT MAKING ANY NOT MAKING
PURIFIED WATER ENOUGH PURIFIED FLASHING INDICATOR WATER LEAKS
WATER EACH BATCH
1. Pudfier power cord not 1. Did not fill tank with 1. Carafe flashing in 1. Water receptacle in
plugged into electrical water to the max. fill line. displayindicates carafeis carafe cover is not open.
outlet, not in posit_on.
2. No power to electrical 2. Carafe is not incorrect 2. Rashing red indicator 2. Carafe cover is not in
outlet, position, light indicates kettle isnot 31ece.
m position.
3. Kettle not plugged into 3. Kettle cover is not 3. Filterflashing in display 3. Carafe isnot in piece.
base receptacle, locked into position, indicates filter needs
changing. _.
4. Did not press reset or 4. Kettle bottom has
start button to start cycle, residue build up.
5. Did notfillthe kettle with
tap water.
6. Carafe is not in
)lace._