INSTALLATION - 2791477A384/A
e
2. Attach the bracket B to the back of the
cooker using the screw A that was removed
in the previous step.
3. Carefully screw the connector 3 to the gas
extension 1, placing the seal provided 2
between them.
4. Screw the assembled extension C to the gas
connector D of the appliance, placing the
provided seal 2 between them.
5. Apply insulating material to the thread of the
assembled extension C.
Burner and nozzle characteristics tables
The nozzles not provided are available at Authorised Service Centres.
Positioning
A: 600 mm (height), measured from the top of
the highest burner and 750 mm from an exhaust
fan. (a mechanical device other than a range
hood for moving air from one interior space to
another, or to outside of the space).
B: 200 mm (vertical combustible surface),
measured from the edge of the nearest burner.
C: 10 mm or more (horizontal combustible
surface) below the hob.
NG 1.0 kPA AUX SR R UR2 int. UR2 ext.
Nominal gas consumption (MJ/h) 3.9 7.5 12 2.6 14.4
Nozzle diameter (1/100 mm) 90 120 155 81 170
Reduced flow rate (MJ/h) 1.4 1.8 2.9 1.4 4.3
ULPG 2.75 kPA AUX SR R UR2 int. UR2 ext.
Nominal gas consumption (MJ/h) 3.9 6.3 10.8 3.0 14
Nozzle diameter (1/100 mm) 54 68 88 48 100
Reduced flow rate (MJ/h) 1.4 1.8 2.9 1.4 5.4
See genral safety instructions.