Service Mode
6:4
Real Time Clock (RTC), Calendar and Time-of-day Discount Promotion.
70 - RTC set-up: 24hr format, “70”>yyyy>D>mm.dd>hh.mm>”70”. During set up, the RTC is
stopped. When the “START” button is pressed to save hh.mm and exit register 70, the
seconds digits of the RTC is set to “00” without a󰀨ecting the hours and minutes values,
and the RTC re-started. For clock setting, “D” is day of week. (1=Sunday, 7=Saturday)
71 - RTC promotion 1 START: “71”>D>hh.mm>%%>71”
72 - RTC promotion 1 END: “72”>hh.mm>72”
73 - RTC promotion 2 START “73”>D>hh.mm>%%>73”
74 - RTC promotion 2 END “74”>hh.mm>”74”
75 - RTC promotion 3 START “75”>D>hh.mm>%%>”75”
76 - RTC promotion 3 END “76”>hh.mm>76”
77 - RTC promotion 4 START “77”>D>hh.mm>%%>77”
78 - RTC promotion 4 END “78”>hh.mm>”78”
79 - Promotion %% for discount input signal (range “00”-”A0”, default=”00, “A0” = 100%)
Select a value identifying the day(s) “D” for which the promotion will be active, as follows:
► 00=promotion is inactive;
► 01=Sunday, 02=Monday, ...07=Saturday;
► 08=All days;
► 09=Monday-Friday only;
► 0A=Saturday and Sunday only;
► 00=promotion is inactive.
Use COLD, WARM, HOT, & DELICATE to edit “yyyy”, “mm.dd”, & “hr.min” values. Press START
to advance to the next entry within the register.
Use HOT and DELICATE to edit the discount percentage “%%. If percentage = 90-99 pressing
DELICATE will set the percentage to “A0” = 100%.
Note:
* = Registers can be accessed in Limited Service Mode.
Resetting the display controller will restore all applicable rmware settings to factory default. The
machine will be set to COIN MODE with all wash program and option prices = 0.00.