201156 - 3650W WIRELESS REMOTE START GENERATOR
OPERATION
26
5. Do not over-choke. As soon as engine starts, move the choke
lever to the “RUN” position over a 2-5 second duration.
NOTICE
Keep choke lever in “CHOKE” position for only 1 pull of the
recoil cord. After first pull, move choke lever to “RUN” position
for up to 3 pulls of the recoil cord. Too much choke leads to
spark plug fouling/engine flooding due to lack of incoming air.
This will cause the engine not to start.
NOTICE
For gasoline restarts with hot engine in hot ambient
temperature > 86°F (30°C), keep choke lever in 75% of the
“CHOKE” position for only 1 pull of the recoil cord. After first
pull, move choke lever to “RUN” position for up to 3 pulls of
the recoil cord. Too much choke leads to spark plug fouling/
engine flooding due to lack of incoming air. This will cause the
engine not to start.
NOTICE
For gasoline starting in cold ambient temperature < 59°F
(15°C), the choke lever must be in 100% of “CHOKE” position
for manual start procedures. Do not over-choke. As soon as
engine starts, gradually move the choke lever to the “RUN”
position over a 2-5 second duration.
NOTICE
For Wireless and Electric Start only: A safety feature is
provided which delays the electrical power availability during
starting mode. The delay lasts for approximately 15 seconds.
The delay is provided to prevent damage to the generator
if electrical loads are inadvertently turned on during engine
startup.
NOTICE
If the engine starts but does not continue to run make certain
that the generator is on a flat, level surface. This engine is
equipped with a low oil sensor that will prevent the engine
from running when the oil level falls below a critical threshold.
Battery
NOTICE
When the battery switch is in the “ON” position, the switch
will light up if the battery is sending out a charge. If the switch
does not light up while in the “ON” position, check that the
battery connection is still good.
NOTICE
The supplied 12V battery does re-charge while the engine
is running and the battery switch is turned ON, but it is also
recommended that the battery be fully charged at least once
per month or maintained with a trickle charger or battery
maintainer (not included).
Connecting Electrical Loads
Let the engine stabilize and warm up for a few minutes after
starting.
Plug in and turn on the desired 120 or 240 (if applicable) Volt AC
single phase, 60 Hz electrical loads.
DO NOT connect 3-phase loads to the generator.
DO NOT overload the generator.
Use only a high quality, insulated, compatible (3-wire or
4-wire) grounded cord set rated equal to or greater (volts and
amps) than the receptacle plugging into.