Loading ...
Loading ...
Loading ...
201156 - 3650W WIRELESS REMOTE START GENERATOR
ASSEMBLY
20
3. The approximate fuel level is shown on the fuel gauge on top
of the fuel tank.
Empty Full
4. Screw on the gasoline cap and wipe away any spilled fuel.
CAUTION
Use unleaded gasoline with a minimum octane rating of 87
and an ethanol content of 10% or less by volume.
DO NOT light cigarettes or smoke when filling the tank.
DO NOT mix oil and gasoline.
DO NOT overfill the tank. Fill tank to approximately ¼ in.
(6.4 mm) below the top of the tank to allow for gasoline
expansion.
DO NOT pump gasoline directly into the generator at the pump.
Use an approved fuel container to transfer the gasoline to the
generator.
DO NOT fill tank indoors.
DO NOT fill tank when the engine is running or hot.
WARNING
Pouring gasoline too fast through the fuel screen may result
in gasoline splashing over the generator and operator while
filling.
NOTICE
The generator engine works well with 10% or less ethanol
blended gasoline. When using ethanol-gasoline blends there
are some issues worth noting:
Ethanol-gasoline blends can absorb more water than
gasoline alone.
These ethanol blends can eventually separate, leaving
water or a watery goo in the tank, fuel valve and
carburetor. The compromised gasoline can be drawn into
the carburetor and cause damage to the engine and/or
create potential hazards.
If a fuel stabilizer is used, confirm that it is formulated to
work with ethanol-gasoline blends.
Any damages or hazards caused by using ethanol blended
gasoline higher than 10% by volume, improperly stored
gasoline, and/or improperly formulated stabilizers, are not
covered by manufacturer’s warranty.
It is advisable to always shut off the gasoline supply and
run the engine to starvation after each use. See Storage
instructions for extended non-use.
Grounding
Your generator must be properly connected to an appropriate
ground to help prevent electric shock.
WARNING
Failure to properly ground the generator can result in electric
shock.
A ground terminal connected to the frame of the generator has
been provided (see Controls and Features for terminal location).
For remote grounding, connect a length of heavy gauge
(12 AWG minimum) copper wire between the generator ground
terminal and a copper rod driven into the ground. We strongly
recommend that you consult with a qualified electrician to ensure
compliance with local electrical codes.
Neutral Floating*
Neutral circuit IS NOT electrically connected to the frame/
ground of the generator.
The generator (stator winding) is isolated from the frame and
from the AC receptacle ground pin.
Electrical devices that require a grounded receptacle pin
connection will not function if the receptacle ground pin is not
functional.
Loading ...
Loading ...
Loading ...