36 - INSTALLATION 91477A886/A
The nozzles not provided are available at Authorised Service Centres.
Electrical connection
General information
Check the mains characteristics against the data
indicated on the plate.
The identification plate bearing the technical
data, serial number and brand name is visibly
positioned on the appliance.
Do not remove this plate for any reason.
The appliance must be connected to ground
using a wire that is at least 20 mm longer than
the other wires.
The appliance can work in the following modes:
220-240 V 1N~
Fixed connection
Fit the power line with an all-pole circuit breaker
with a contact separation distance sufficient to
provide complete disconnection in category III
overvoltage conditions, pursuant to installation
regulations.
For the Australian/New Zealand market:
The circuit breaker incorporated in the fixed
connection must comply with AS/NZS 3000.
Connection with plug and socket
Make sure that the plug and socket are of the
same type.
Avoid using adapters, gang sockets or shunts as
these could cause overheating and a risk of
burns.
Section cut from the countertop
Safety instructions for positioning and
installation
Installation can be carried out on various
materials such as masonry, metal, solid
wood or plastic laminated wood as long as
they are heat resistant (>90°C).
Veneers, adhesives or plastic coatings on
adjacent furniture should be temperature-
resistant (>90°C), otherwise they might
warp over time.
If the piece of furniture does not have the
required recess opening, either it will have
to be cut or masonry work carried out by a
5 LPG G30/31 - 30/37 mbar AUX SR RR R1 R2
Rated heating capacity (kW) 1.1 1.70 2.6 3.2 3.0
Nozzle diameter (1/100 mm) 48 62 76 85 82
Reduced flow rate (W) 400 500 750 1050 1050
Primary air (mm) 4 2 2 10 3
Rated flow rate G30 (g/h) 80 124 189 233 218
Rated flow rate G31 (g/h) 79 121 186 229 214
6 LPG G30/31 - 37 mbar AUX SR RR R1 R2
Rated heating capacity (kW) 1.1 1.7 2.55 3.2 3.0
Nozzle diameter (1/100 mm) 48 60 72 73 78
Reduced flow rate (W) 450 500 850 1050 1200
Primary air (mm) 4 2 1.5 1.5 2
Rated flow rate G30 (g/h) 80 124 186 233 218
Rated flow rate G31 (g/h) 79 121 182 229 214
7 Town gas G110 – 8 mbar AUX SR RR R1 R2
Rated heating capacity (kW)
1.1 1.7 2.6 3.2 2.9
Nozzle diameter (1/100 mm)
132 165 230 270 250
Reduced flow rate (W)
400 500 750 1050 1050
Primary air (mm)
10.5 1 1 1
See General safety instructions.
The values indicated refer to the cross-
section of the internal conductor.
See General safety instructions.