49-1000588 Rev. 0 17
ENGLISH
ACCESSORY
MOUNT THE ICEMAKER
Before installing the icemaker, swap the feeler arm
on the icemaker with a longer one, if shipped with the
refrigerator (included in the bag with owner’s manual
and instruction sheet).
For easy installation, remove freezer drawer
Make sure the power cord is still in the hook on the back
of the icemaker.
Use two 7/8” Phillips Head Screws to mount the
icemaker. Drive one mounting screw halfway into right
screw hole on the support bracket on the left side upper
wall in the freezer compartment
Lift the icemaker so the fill tube fits in the fill cup
opening. Hang right L-shaped tab of icemaker onto the
mounting screw
Lift the icemaker so the upmost slot of left L-shaped tab
is aligned with the left screw hole on support bracket,
then drive the other mounting screw halfway through
the slot into the left screw hole
Insert the icemaker power cord plug into the socket on
the wall, making sure the prongs and holes are matched.
Press the plug firmly into the place by clipping the
restraints onto each side of the plug
Make sure:
The power cord is still firmly in the socket.
The fill tube assembly extends into the fill cup opening
at the back of the icemaker.
The icemaker mounting screws should be located in
the uppermost position of the mounting slots on the
icemaker bracket.
The icemaker is level.
The icemaker power switch is in the OFF position.
SECURELY TIGHTEN THE ICEMAKER MOUNTING
SCREWS.
Mounting
screws
L-shaped
tab
Fill cup
Fill tube
Icemaker
support
bracket
WATER VALVE INSTALLATION
REMOVE THE COVER
Remove the access cover. This requires removing screws
which attach the
cover to the back of the refrigerator case.
Be sure to save the screws as
the access cover must
be reinstalled later to ensure
your refrigerator will function
properly.
WARNING
To reduce the risk of death or electric
shock, you must follow these instructions:
¿ Unplug the refrigerator before removing any panels.
¿ Do not damage any wiring while the panel is
removed.
¿ Replace all parts and panels before plugging the
refrigerator back in.
READ AND SAVE THESE INSTRUCTIONS
Refer to WATER VALVE INSTALLATION INSTRUCTIONS -
IM4D ONLY in the IM4D Icemaker Kit’s Owner’s Manual.