Replace the HEPA filter in case of damage
The HEPA filter should be cleaned at intervals of 4
months.
Ensure the correct positioning of the HEPA filter in
the holder.
Relock the HEPA filter by means of the lever.
Often, failures have simple causes and you can do the
troubleshooting yourself using the following overview. If
you are in doubt or if the failure is not listed here please
contact the authorized customer service.
DANGER
Mortal danger due to electric current.
Turn off the appliance and remove the mains plug
prior to any care and maintenance work.
Allow device to cool down.
Repair works may only be performed by the author-
ised customer service.
Remove the mains plug, check the connecting ca-
ble and the mains plug for damage.
If accessories/suction hose/suction pipes are clogged
or kept shut for more than 10 seconds, a vacuum devel-
ops and the electronics switches off the motor for safety
reasons.
Turn off the appliance.
Remove blocking.
Turn on the machine.
Accessories, suction hose or suction tubes are
clogged, please remove the obstruction.
Clean water filter insert.
Change the water in the water filter container.
Replace the HEPA filter.
Change the water in the water filter container.
Clean the lid of the water filter container.
Switch off the vacuum cleaner, ensure that the wa-
ter level in the reservoir is correct and switch on the
machine again.
Subject to technical modifications!
Troubleshooting
Appliance does not vacuum
Power supply is interrupted
Accessories/suction hose/suction pipes are
clogged or kept shut
Weak/diminishing suction power
Accessory is blocked
HEPA filter is soiled
Poor cleaning performance
Water in the water filter container is very dirty
Water leaks out while sucking in fluids
The float switch is blocked
The vacuum cleaner does not suck
Float switch is blocking
Technical specifications
Electrical connection
Voltage 220-240
1~50-60
V
Hz
Protection class IP X4
Protective class I
Performance data
Boiler capacity 1100 W
Rated power turbine 1100 W
Max. steam pressure 0,4 MPa
Heating time 5 Minutes
Max. steam quantity 65 g/min
Filling quantity
Boiler capacity 0,45 l
Water reservoir 0,5 l
Water filter container 1,2 l
Dimensions
Length 510 mm
Width 330 mm
Height 340 mm
Weight (without accessories) 9,1 kg
Sound
Sound pressure level (EN 60704-2-1) 71 dB(A)
20 EN