Haier 1U12EH2VHE Arctic Series 208-230V 12,000 BTU Ductless Mini-Split Outdoor Heat Pump System

User Manual - Page 89

For 1U12EH2VHE.

PDF File Manual, 117 pages, Read Online | Download pdf file

1U12EH2VHE photo
Loading ...
Loading ...
Loading ...
Troubleshooting
See reverse side for
wiring diagram and
relevant color-coded
test positions.
No
Error Code (Indoor/Outdoor)
F8/LED1: 9 Flash
Complete the “Check This First” Flow
Chart before continuing.
Models:
AW09EH2VHD/ASYW09URDWD
AW12EH2VHD/ASYW12URDWD
AW18EH2VHD/ASYW18URDWD
1U09EH2VHE/ASH109URDSE
1U12EH2VHE/ASH112URDSE
1U18EH2VHE/ASH118URDSE
Yes
Yes
Yes
Yes
No
Yes
No
Yes
No
protection from wind.
Fix incoming power supply
Replace the fan motor
Replace the
fan motor.
Replace the
main board.
Start
Check the incoming voltage.
Is it 208/230VAC (+/- 10%) between L1/L2?
104/115VAC (+/- 10%) from L1 to GROUND and L2 to GROUND?
Does it move / rotate smoothly?
Re-apply power. Does the
fan come on and spin?
Measure DC voltage at fan motor plug
CN21 between the Pin 6 (BLUE) and Pin 3
(BLACK) wire while spinning the fan motor.
Does it generate 2~9VDC?
No
No
No
Replace the
main board.
Replace the
main board.
Replace the
main board.
Measure DC voltage at fan motor plug CN21
between Pin 1 (RED) and Pin 3 (BLACK).
Does it measure 300~380VDC (+/-10%)?
Measure DC voltage at fan motor plug CN21
between Pin 4 (WHITE) and Pin 3 (BLACK).
Does it measure between 13.5-16.5VDC?
Measure DC voltage at fan motor plug CN21
between Pin 5 (YELLOW) and Pin 3 (BLACK).
Does it measure between 2-6VDC?
Before going to the next step, is the
unit in an area susceptible to high
winds? High winds blowing into the
fan may cause added resistance
and subsequently lower fan speeds
enough to cause the unit to fault. If
this is the case the unit only faults
may need to be added.
Not Windy Windy
Yes
ERROR CODES and Troubleshooting
PAGE 89
Loading ...
Loading ...
Loading ...