Also, The document are for others Haier models: 1U09EH2VHE, 1U18EH2VHE, ASH109URDSE, ASH112URDSE, ASH118URDSE, AW09EH2VHD, AW12EH2VHD, AW18EH2VHD, ASYW09URDWD, ASYW12URDWD, ASYW18URDWD, AB09SC2VH, AB12SC2VH, AB18SC2VH, USYF09UCDWA, USYF12UCDWA, USYF18UCDWA, 1U09EH2VHD, 1U12EH2VHD, 1U18EH2VHD, ASH109URDSD, ASH112URDSD, ASH118URDSD, AWO9EH2VHD

PDF File Manual, 117 pages, Read Online | Download pdf file

1U12EH2VHE photo
Loading ...
Loading ...
Loading ...
Troubleshooting
See reverse side for
wiring diagram and
relevant color-coded
test positions.
Yes
Yes
Yes
Start
No
No
No
No
No
Line voltage at AC-L & AC-N
on the PCB (CN2 & CN1)?
Line voltage at AC-L & AC-N
on the IPM (9K CN8 & CN9 /
12K/18K CN1 & CN2)?
Module Power voltage -
CN22 on the PCB:
Across pins 1 & 2 = 5VDC
Across pins 2 & 3 = 15VDC?
Module Power voltage -
CN10 on the IPM
Across pins 1 & 2 = 5VDC
Across pins 2 & 3 = 15VDC?
Module Com voltage - CN23 on the PCB
With a call for Heating or Cooling,
Across pins 1 & 2 = 5VDC
Across pins 2 & 3 = 15VDC ?
Module Com voltage - CN11 on the IPM
With a call for Heating or Cooling,
Across pins 1 & 2 = 5VDC
Across pins 2 & 3 = 15VDC?
Yes
Yes
Yes
No
Yes
No
Yes
No
Check incoming power
from building
Replace PCB
Replace PCB
Replace fuse
Replace AC-L & AC-N
wiring harness
Replace module
power wiring
harness
Replace Module
COM Wiring
Harness
Replace PCB
Replace IPM
Fuse 1 is OK?
Line voltage at
AC-L OUT & AC-N
OUT on the PCB
(CN8 & CN9)?
Error Code (Indoor/Outdoor)
F3/LED1: 4 Flash
Complete the “Check This First” Flow
Chart before continuing.
Models:
AW09EH2VHD/ASYW09URDWD
AW12EH2VHD/ASYW12URDWD
AW18EH2VHD/ASYW18URDWD
1U09EH2VHE/ASH109URDSE
1U12EH2VHE/ASH112URDSE
1U18EH2VHE/ASH118URDSE
ERROR CODES and Troubleshooting