Cookware do
not become hot
and the symbol
appears in
the display.
The induction hob cannot
detect the cookware
because it is not suitable for
induction cooking.
The induction hob cannot
detect the cookware
because it is too small for
the cooking zone or not
properly centred on it.
Use cookware suitable for induction
cooking. See section ‘Choosing the
right cookware’.
Centre the cookware and make
sure that its base matches the size
of the cooking zone.
Failure Display and Inspection
If an abnormality comes up, the induction hob will enter the protective state
automatically and display corresponding protective codes. These are the most common
failures:
Error
Message
Possible causes What to do
No cookware or cookware not
suitable.
Replace the cookware.
ER03
Water or cookware on the glass
over the control area.
Clean the control area.
F1E
Connection between the display
board and the left mainboard fails
(the cooking zone which indicator
shows “E”).
Contact the Technical Service
F3E
Coil temperature sensor failure.
(in the cooking zone which
indicator shows “E”).
Contact the Technical Service
F4E
Mainboard temperature sensor
failure. (in the cooking zone which
indicator shows “E”).
Contact the Technical Service
E1E
Temperature measured by the
sensor of the ceramic glass is too
high.
Please restart after the hob has
been cooled down.
E2 E
Temperature sensor of the IGBT is
too high.
Please restart after the hob has
been cooled down.
E3 E
Abnormal supply voltage (too
high).
Please inspect whether power
supply is normal. Switch on after
the power supply is normal.