5.1 Lubricant oil
Oil level must be checked every time;
First time oil change : 50 hours, 0.5-0.6 liters
Regular oil change : 100 hours or annually
Lubricant oil features : ISO VG46, AW46
Warning : it is forbidden to mix different brand or ISO grade oil for lubricate, recommend MOBIL
827/829 or equivalent
5.2 Filtration for air
The better outlet air quality will be got if use extra purification,
filter elements must be highly efficient fibrous materials and must be replaced periodically.
5.3 High pressure air hose
The air hose must be replaced regularly 1000 hours or
annually, bending radius does not exceed 250mm. With
8mm quick connector, connect directly to tank valve fitting.
5.4 Air filter
Us compressed air to blow air filter to clean dust. The air filter
must be changed every 100 working hours or annually.
Note : We would suggest to change filter every 50 hours if the compressor is used in dusty
environment.
5.5 Condensate drain
Drain condensate after every refill, Open the drain screw to
drain out Normal condensate is milk white or brown white
with a little few resident oil,
If the condensate is in black or oil smell, check lube oil quality or change oil
5.6 Accessories come with
Water pump
Water pipe
Air filling hose
Breather
Spare parts kit
Loading ...