Loading ...
Loading ...
Loading ...
4 HCC1010A/W, HCD1010A/W, HCC1410A/W, HCD1410A/W
Specications
Electrical
Each ice machine requires its own separate circuit with electrical disconnect within 10 ft (6m).
Equipment ground required.
Standard electrical:
§ HCC1010: 208-230/60/1 (6 ft (2m) NEMA 6-15 cord and plug provided)
§ HCC1410: 208-230/60/1 (6 ft (2m) NEMA 6-20 cord and plug provided)
§ Amperage: 1010A/W - 11A
1410A/W - 14A
Plumbing
WARNING
This equipment to be installed with adequate backow protection to comply with applicable federal, state,
and local codes.
§ 3/8" OD push-in water inlet (connection inside machine) - 3/8" OD tubing required
§ 3/4" MPT drain
§ 1/4" FPT condenser inlet (water-cooled condenser only)
§ 1/4" FPT condenser drain (water-cooled condenser only)
Notes:
§ Water shut-off recommended within 10 feet (3m).
§ Water supply must have particle ltration. Follett recommends the lter system that has integral scale inhibitors.
(Follett item# 00130286).
§ Follett does not recommend the use of water softeners or bowl scale inhibitors.
Flush drain plumbing
§ 3/4" MPT ush drain connection at the rear of the machine.
§ Drain must slope 1/4" inch per foot (6 mm per 30.4 cm).
§ Drain line should not be shared with any other piece of equipment.
§ Drain line cannot be reduced to a size smaller than 1 inch.
§ Drain should be piped without a vent.
3/4" barb x 3/4" FPT
1" Stand pipe/Drain
2 ft. x 1" OD
silicone tubing
Minimum 8"
radius
3/4" MPT x 1" slip
1" PVC Drain
2 ft. x 1" OD
silicone tubing
3/4" MPT x 1" slip
3/4" barb x 3/4" FPT
1'
1/4" per foot
(6,4 mm per 0,3 m)
Loading ...
Loading ...
Loading ...