Waldorf RNLB8610GEC Bold 900mm Gas Range Electric Convection Oven Low Back Version

Installation Operation Manual - Page 8

For RNLB8610GEC.

PDF File Manual, 37 pages, Read Online | Download pdf file

RNLB8610GEC photo
Loading ...
Loading ...
Loading ...
6
RN8510 / RN8610GE / GEC Models Only.
Electrical supply connection point is located at rear of appliance, approximately 80mm from right
hand side, 466mm from rear and 150mm from floor.
RN8810GE/GEC Models Only.
Electrical supply connection point is located at rear of appliance, approximately 380mm from right
hand side, 466mm from rear and 150mm from floor.
When connecting this electric appliance to mains supply, ensure following is carried out:-
An isolating switch is fitted within 2m of appliance, but not on appliance and in such a
position that user does not have to reach across cooking surface.
Supply cord shall be oil-resistant, sheathed flexible cable and not lighter than ordinary
polychloroprene or other equivalent synthetic elastomer sheathed cord (as per AS / NZS
3191 part 2.10.11. or IEC 60245-IEC-57) e.g. HO5 RN-F Type.
Branch supply line shall be individually overload protected to correct current rating and
supply chord shall be protected against any mechanical or thermal damage.
A grommet is fitted around wiring entry hole into appliance.
All wiring connections must be tight.
Refer to appropriate wiring standards for size of cable to be supplied to an appliance for current
drawn on that line.
MODEL
1-Phase Connection
1P+N+E, 230-240V
3-Phase Connection
3P+N+E, 400-415V
RN8510GE
5.5 kW,
22.6 Amps @ 235 V
5.5 kW
L1 - 7.2 Amps
L2 - 7.7 Amps
L3 - 7.7 Amps
RN8510GEC
5.8 kW,
23.9 Amps @ 235 V
5.8 kW
L1 - 8.5 Amps
L2 - 7.7 Amps
L3 - 7.7 Amps
RN8610GE
6.5 kW,
26.6 Amps @ 235 V
6.5 kW
L1 - 8.2 Amps
L2 - 9.2 Amps
L3 - 9.2 Amps
RN8610GEC
6.8 kW,
27.9 Amps @ 235 V
6.8 kW
L1 - 9.5 Amps
L2 - 9.2 Amps
L3 - 9.2 Amps
RN8810GE
6.5 kW,
26.6 Amps @ 235 V
6.5 kW
L1 - 8.2 Amps
L2 - 9.2 Amps
L3 - 9.2 Amps
RN8810GEC
6.8 kW,
27.9 Amps @ 235 V
6.8 kW
L1 - 9.5 Amps
L2 - 9.2 Amps
L3 - 9.2 Amps
THIS APPLIANCE MUST BE EARTHED. IF THE SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY A SUITABLY
QUALIFIED PERSON IN ORDER TO AVOID A HAZARD.