Waldorf RNLB8610GEC Bold 900mm Gas Range Electric Convection Oven Low Back Version

Installation Operation Manual - Page 33

For RNLB8610GEC.

PDF File Manual, 37 pages, Read Online | Download pdf file

RNLB8610GEC photo
Loading ...
Loading ...
Loading ...
31
- All Other Markets:
NOTE:
(*) Measure Burner operating pressure at manifold test point with two burners operating at
'High Flame' setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted,
unless when converting between gases, if required.
(**) TOWN GAS Only - Adjust burner operating pressure using adjustable gas regulator
supplied.
Refer to information in this section for further details.
Open Burner
Main Burner Ø 2.45mm Ø 4.50mm
Pilot Burner ('PF' Option Only) 0.30 0.60
Griddle
Main Burner Ø 2.10mm Ø 3.40mm
Pilot Burner 0.35 0.60
Burner Aeration Setting Fully open Fully open
Supply Pressure 1.13 - 3-4 kPa 0.75 - 1.50 kPa
Burner Operating Pressure (*) 0.95 kPa 0.63 kPa
Gas Regulator Cap Screw
Adjustable Regulator
(Adjust to Burner Operating
Pressure specified).
Open Burner
Main Burner
Ø 1.50mm Ø 1.40mm
Pilot Burner ('PF' Option Only)
0.20 0.20
Griddle
Main Burner
Ø 1.30mm Ø 1.20mm
Pilot Burner
0.23 0.23
Burner Aeration Setting
Fully open
Supply Pressure
2.75 - 4.50 kPa
Burner Operating Pressure (*)
2.6 kPa
Gas Regulator Cap Screw