- 8 -
1. Jaws
Used for clamping the conductor for current measurements. The
conductor should be positioned at the center of the jaws during
measurement.
2. Trigger
Used to open and close the jaws.
3. " " Button
With the meter on, press this " " button to turn on oroff the backlight.
The backlight will turn off automaticallyafter about 30 secs.
4. Function Selector Button
Used to switch between:
DC current, AC current, VFD current and inrush current measurement
functions.
DC voltage and AC voltage measurement functions.
Resistance, diode, continuity and capacitance test functions.
5. "
" Button
Used to enter or exit the MIN MAX mode.
6. Display
3
5
/
6
digits LCD.
7. " COM " Terminal
Plug-in connector for the black test lead.
8. " INPUT " Terminal
Plug-in connector for the red test lead.