The 48-Bus Mod provides an extra set of Multi-track Bus Outputs,
forming Multi-track Buses 25-48. Where the rst 24 channels of
the console have access to buses 1-24, and subsequent channels
have access to 25-48. Buses 25-48 do not have access to bus
master trims and so exit the console at unity gain. It is also worth
noting that the Stereo EFX Inputs are only routable to buses 1-24.
With the Bus Mod installed, the console can be operated in two
modes, Bus Split and Bus Link:
In Bus Split mode, channels 1-24 can access Multi-track buses
1-24, whilst channels 25+ can access 25-48, providing up to 48
discrete outputs from the console.
In Bus Link mode, the 25-48 combiners are summed into the
original 1-24 Multi-track buses to provide standard 24-bus
operation across the entire console.
When no Bus Mod option is installed, the Bus Link switch
becomes a handy DFA button for those all important production
decisions...