Jenn-Air's ventilation system is designed to capture both cooking fumes and smoke
while grilling. If the system does not, these are some ducting installation situations to
check:
• 6" diameter round or 3 1/4" x 10" rectangular ducting should be used. Note: 5"
diameter round ducting may be used if the duct length is 10' or less.
• No more than three 90° elbows should be used. Distance between elbows should
be at least 18".
• Recommended Jenn-Air walt cap should be used. Make sure damper moves freely
when ventilation system is operating.
i There should be a minimum clearance of 6" for cooktop installed near a side wall.
If there is not an obvious improper installation, there may be a concealed problem such
as a pinched joint, obstruction in the pipe, etc. Insta!_ation is the..responsibility of the
installer and questions should be addressed first by the installer. The installer should
very carefully check the ducting installation instructions.