71
TROUBLESHOOTING
Mode Description Solution
Engine will not start
Battery not charged Charge battery
Engine switch is in the “OFF”
position
Turn engine switch to the “ON”
position
Stale gasoline or water in gaso-
line
Drain entire system and rell
with fresh fuel
Engine is out of fuel Add fuel
Fuel is old or contaminated Change fuel
Spark plug is dirty Clean spark plug
Spark plug is broken Replace spark plug
Generator is not level
Move generator to a level
surface
Oil is low Add/Change oil
Engine runs, but there
is no electrical output
Circuit breaker is “OFF” Turn “ON” circuit breaker
Wiring connection is bad Replace extension cord(s)
Device connected to generator
is malfunctioning
Disconnect malfunctioning
device
Generator runs, but
does not support all
electrical devices
connected
Generator is overloaded
Disconnect 1 or more items to
reduce the load
Device connected to generator
is bad
Disconnect malfunctioning
device
Air cleaner is dirty Clean/Replace the air lter