Emptying the Gas Tank
MAINTENANCE AND CARE (CONTINUED)
60
Remove left service cover
Remove fuel hose clip
Bend center of fuel hose
Remove left service cover to allow access to the gasoline fuel
line.
Follow fuel hose from the bottom of the gas tank until you
reach the rst connection point and remove the fuel line clip
with pliers. NOTE: Do not remove fuel hose from connection
point yet.
Bend the center of fuel hose to cut the ow of gasoline on fuel
line.
1.
2.
3.
CAUTION: Do not store fuel from one season
to another. Gasoline sold at the pump today
contains additives such as ethanol that even
when stored properly may damage the fuel
system components.
If you have been using gasoline in your generator, before
storing your generator for extended periods of time you
should drain your generator fuel tank of gasoline.