16
TROUBLESHOOTING
You can solve many common problems easily, possibly saving you the cost of a service call. Try the
suggestions below to see if you can solve the problem before calling the servicer.
PROBLEM
POSSIBLE CAUSE
REMEDY
The
appliance
does not
operate
The appliance is not connected to a power
source
The appliance is turned off
A triple circuit breaker or blown fuse
Connect the appliance to a power source
Turn on the appliance
Turn the circuit breaker on or replace the
fuse
The
appliance is
not cold
enough
The temperature is not set correctly
The drawer is opened too often
The drawer was not closed completely
The drawer is not hermetically sealed
The condenser is too dirty
The ventilation opening is blocked or is too
dusty
Check the set temperature. The ambient
temperature could require a lower
temperature setting, set a lower temperature
Do not open the drawer more often than
necessary
Close the drawer properly
Check the seal and clean or replace it
Clean the condenser, when necessary
Clear any obstructions and wipe off the dust.
The
appliance
turns itself on
and off
frequently
The ambient room temperature is higher
than average
A large amount of food has been added to
the appliance
The drawer is opened too often
The drawer is not closed completely
The drawer gasket does not seal properly
Place the appliance in a location with a
cooler ambient temperature
Leave the appliance to work until the set
temperature has been reached
Do not open the drawer more often than
necessary
Close the drawer properly
Check the drawer seal and clean it or
replace it.
The light
does not
work
The appliance is not connected to a power
supply
A tripped circuit breaker or a blown fuse
The light is switched off on the control
panel
Connect the appliance
Turn the circuit breaker on or replace the
fuse
Switch on the light
Vibration
The appliance is not properly leveled
Level the appliance using the adjustable feet
The
appliance
makes too
much noise
The appliance is not properly leveled
Level the appliance with the adjustable feet
The drawer
will not close
properly
The appliance is not properly leveled
The gasket is dirty
The baskets or bins are out of position
Level the appliance with the adjustable feet
Clean the drawer gaskets
Check the baskets and bins and refit them
correctly.
Display “LL,”
“EE”
“LL” indicates the temperature sensor open
circuit
“EE” indicates the temperature sensor
short circuit
Call for service.