JET ESR-1650-3T , Electric Slip Roll, 50" x 16-Gauge, 3Ph 230/460V

Manual - Page 11

For ESR-1650-3T.

PDF File Manual, 20 pages, Download pdf file

Loading ...
Loading ...
Loading ...
11
13.0 Troubleshooting the ESR-1650T Slip Roll
Trouble Probable Cause Remedy
Slip roll doesn’t
operate; rolls won’t
move.
No incoming power.
Check power source and
connections.
Emergency stop engaged.
Release emergency stop switch by
rotating clockwise (check both switch
locations).
Jam nut is loose. Tighten nut to secure stationary roll.
Gears damaged.
Inspect gears; repair/replace as
needed.
Cones are made
when trying to make
cylinders.
Rolls not parallel.
Adjust idle (rear) roll as needed until
idle roll is parallel to stationary (top)
roll.
Workpiece is not
bending.
Machine capacity exceeded.
Use materials within machine’s
capacity.
Idle Roll not engaging.
Inspect idle roll; make adjustments as
needed.
14.0 Replacement Parts
Replacement parts are listed on the following pages. To order parts or reach our service department, call
1-800-274-6848, Monday through Friday (see our website for business hours, www.jettools.com). Having
the Model Number and Serial Number of your machine available when you call will allow us to serve you
quickly and accurately.