Tripp Lite SMART1000LCDU 1000VA Smart UPS Back Up

Owner’s Manual - Page 6

For SMART1000LCDU.

PDF File Manual, 24 pages, Read Online | Download pdf file

SMART1000LCDU photo
Loading ...
Loading ...
Loading ...
6
Basic Operation
USB Charging Port: Charge-only USB port that delivers up to 2.2 A of charge
current for use with cell phones, Smartphones, MP3 players and other devices that
are compatible with USB chargers.
Note: This port is intended for USB charging only. USB communication is not accessible
through this port.
Note: USB charging is only available when the UPS is on and receiving utility power.
Surge-Only Protected Outlets: Provide surge and line noise protection, not
battery backup. Plug equipment that does not require battery backup during a
utility power failure (such as a printer, scanner or fax machine) into these outlets.
Battery Backup Protected/Surge Protected Outlets: Provide both battery
backup and surge protection. Plug your computer, monitor and other critical
equipment into these outlets.
NOTE: DO NOT PLUG LASER PRINTERS INTO THESE OUTLETS.
USB Communication Port (HID Compliant): This port can connect your UPS to a
computer in order to automatically save open files and shut down the computer if
it is left unattended during an extended power failure. Use with Tripp Lite’s
PowerAlert software and appropriate USB cable. PowerAlert software can be
obtained for free via the Web at www.tripplite.com and a USB cable is included
with your UPS. Download the software to your computer and follow the installation
instructions. Any user-supplied USB cable may be used to connect your UPS to
your computer.
Note: This connection is optional. The UPS will work properly without this connection.
Note: This UPS System automatically provides basic communication compatibility with many
integrated Windows
®
, Macintosh
®
and Linux
®
power management applications.
Tel/DSL Protection Jacks: RJ-style jacks protect connected equipment by
stopping surges on a single phone, fax or modem line. Connect a phone cord from
the wall jack directly to the Tel/DSL jack labeled “IN.” Connect a phone cord from
the Tel/DSL jack labeled “OUT” directly to the device to be protected. The UPS
system must always be the first item connected in line from the wall jack. The UPS
system must be plugged into a 3-wire grounded AC outlet for Tel/DSL line surge
protection to work. Connecting your equipment to these jacks is optional. Your UPS
will work properly without this connection.
Coaxial Protection Jacks: Gold-plated coaxial “F” connectors protect connected
equipment by stopping surges on a single DSS satellite, cable or antenna line.
Connect a coaxial cable from the wall jack directly to the coaxial jack labeled “IN.”
Connect a coaxial cable from the coaxial jack labeled “OUT” directly to the device
to be protected. The UPS system must always be the first item connected in line
from the coaxial wall jack. The UPS system must be plugged into a 3-wire
grounded AC outlet for coaxial line surge protection to work. Make sure cables
connected to satellite dishes, antennas, etc. are also grounded. Connecting your
equipment to these jacks is optional. Your UPS will work properly without this
connection.
Battery Replacement Door: Under normal conditions, the original battery in your
UPS will last several years. Battery replacement should be performed only by
qualified service personnel. Refer to “Battery Warnings” in the Safety section.
Should your UPS require battery replacement, visit Tripp Lite on the Web at
http://www.tripplite.com/products/battery-finder/ to locate the specific replacement
battery for your UPS.
Front Panel
Rear Panel
15-06-324-9334A3.indb 6 8/6/2015 4:23:09 PM
Loading ...
Loading ...
Loading ...