18 INSTALLATION
d Power Cord Ground Wire
e Ground Screw (green)
Three-Wire Power Cord
1 Remove the terminal block access cover on
the upper back of the appliance.
2 Install the UL-listed strain relief into the
power cord through-hole.
3 Thread a 30-amp, 240 volt, 3-wire, UL-listed
power cord with #10 AWG-minimum copper
conductor through the strain relief.
a Terminal Block
b UL-Listed Strain Relief
c UL-Listed 3-Wire Power Cord
4 Attach the two hot leads (black and red) of the
power cord to the outer terminal block
screws.
5 Attach the neutral (white) wire to the center
terminal block screw.
6 Connect the external ground (if required by
local codes) to the green ground screw.
7 Tighten all screws securely.
8 Reinstall the terminal block access cover.
a White Wire from Dryer Harness
b Hot Leads of Power Cord (Black and Red)
c Neutral Wire (White)
d External Ground Wire (If required by local
codes)
e Ground Screw (green)
Three-Wire Direct Wire
1 Remove 3.5 inches (8.9 cm) of the outer
covering from the wire. Strip 1 inch (2.5 cm)
insulation from each wire. Bend the ends of
the three wires into a hook shape.
2 Remove the terminal block access cover on
the upper back of the appliance.
3 Install UL-listed strain relief into the power
cord through-hole.
4 Thread the 3-wire, #10 AWG minimum copper
conductor power cable prepared in step 1
through the strain relief.
A 3-wire connection is NOT
permitted on new construction after
January 1, 1996.
A UL-listed strain relief is required.
Use a 30-amp, 240-volt, 3-wire, UL-listed
power cord with #10 AWG-minimum copper
conductor and closed loop or forked terminals
with upturned ends.
A 3-wire connection is NOT
permitted on new construction after
January 1, 1996.
A UL-listed strain relief is required.
Use UL-listed 3-wire, #10 AWG minimum
copper conductor cable. Allow at least 5 ft. (1.5
m) length to allow for removal and installation
of dryer.
1’’ (2.5 cm)