29INSTALLATION
ENGLISH
Restricted or Blocked Airflow
Avoid long runs or runs with multiple elbows or
bends.
Excess or crushed transition duct
Too many elbows or exhaust too long
Check for blockages and lint buildup.
Error
Messages
Possible Cause & Solution
Temp
Sensor
Error 1
Temperature sensor failure.
Turn off the appliance and call for
service.
Humidity
Sensor
Error
Humidity sensor failure.
Turn off the appliance and call for
service.
Power
Supply /
High
Voltage /
Low
Voltage
Electric dryer power cord is not
connected correctly, or house
power supply is incorrect.
Reset circuit breaker or replace
fuse. Do not increase the fuse
capacity.
House fuse is blown, circuit
breaker has tripped, or power
outage has occurred.
If the problem is a circuit
overload, have it corrected by a
qualified electrician.
Gas
Supply
Gas supply or service turned off.
(Gas Model only.)
Confirm that house gas shutoff
and the dryer gas shutoff are
both fully open.
Duct
Blockage
(80%) /
Duct
Blockage
(90%) /
Duct
Blockage
(95%)
Exhaust system is too long or has
too many turns/restrictions.
Do not use the appliance until
the exhaust system has been
cleaned and/or repaired. Using
the appliance with severely
restricted exhaust is dangerous
and could result in a fire or other
property damage.
Check the outside dryer vent
while the appliance is operating
to make sure there is strong
airflow. If the exhaust system is
extremely long, have it repaired
or rerouted.
Door
Open
Door open error.
Do not open the door when
doing installation mode. Restart
Installation mode.