14
REMOTE CONTROL
1) Power On and Off - When the unit is plugged in, press the POWER button to turn on the
unit. Press the POWER button once more to turn the unit off.
2) Mode Selection - Press the Cool, Dry, Fan mode.
3) Fan Speed - Press the High or Low button to adjust the fan speed. When the unit is in Dry
mode, the fan speed cannot be changed.
4) Temperature Setting - When the unit is in cool mode, you can select your desired
temperature. Press the or to select your desired temperature setting.
5) SLEEP MODE - When in air conditioning mode, press the SLEEP Button on the remote
control.
6) TIMER
Auto-On: Press the TIMER button when the unit is off to set up the Auto-on timer. Press the
or to set timer within 1-24 hours.
Auto-Off: Press the TIMER button when the unit is On to set up the Auto-off timer. Press the
or to set timer within 1-24 hours. To cancel the timer, press the TIMER button until the timer
mode is turned off.
7) ºC/ ºF
Press this button to switch temperature unit.
NOTE:
Insert the two AAA batteries.
Do not use rechargeable batteries.
When replacing the battery, please replace the 2
batteries at the same time. Do not mix old and new
batteries.
If you do not use this unit for a long time, please take
out the battery of the remote control and store it
properly.
WARNING
If the battery liquid of the remote control leaks on your skin or clothes, please rinse with plenty of water as
soon as possible; if you find a leak, please do not use the remote control.
If you swallow the battery liquid, rinse your mouth and seek medical attention as soon as possible. The
chemical substances in the battery may burn or cause other health hazards.
SAFETY PROTECTIONS
1. Water-full safety alarm and shut off protection function
When the water volume exceeds its alarm level in chassis, warning sounds and a water-full icon will light up in display, you
need to drain the water and re-start the unit. (For more information about how to drain, refer to the “Drainage Instruction”
please). If the unit is not shut down manually, the unit will recover to the original operating status automatically once the
water is fully drained. Or connect the power to re-start the unit again.
2. Anti-frozen protection function (Optional)
Under COOLING mode, when the compressor continuously runs over 10 minutes, if tube temperature is ≤2 ºC /36 ºF
for 20 seconds, the anti-frozen protection function will be on, E4 will be shown on LED display, compressor and water wheel
motor will stop working, but upper fan remains running; If tube temperature ≥8 ºC /46 ºF, the unit will stop
anti-frozen protection and recover to the original working condition. Compressor will re-start working with 3 minutes delay
for protection.