Loading ...
Loading ...
Loading ...
![](https://files.manualsfile.com/8047885-khgd4-60510/bg8.png)
8
INJECTORS TABLE CATEGORY II2H3+
Type of gas
used
Type of burner Injector
marking
Rated
thermal
ow rate
kW
Rated
consumption
Reduced
heat
capacity
kW
Gas pressure
mbar
min. rat. max.
NATURAL GAS
(Methane) G20
Semi-rapid
Auxiliary
DCC - Outer + Inner
DCC - Inner
93 A
78 C
149 H3 +70 HI
70 HI
1,65
1,00
3,70
0,90
167 l/h
95 l/h
352 l/h
86 l/h
0,35
0,30
2,20
0,30
17 20 25
LIQUEFIED
PETROLEUM GAS
(Butane) G30
Semi-rapid
Auxiliary
DCC - Outer + Inner
DCC - Inner
68 A
50 A
80 + 41
41
1,65
1,00
3,30
0,90
127 g/h
73 g/h
240 g/h
65 g/h
0,35
0,30
1,90
0,30
20 28-30 35
LIQUEFIED
PETROLEUM GAS
(Propane) G31
Semi-rapid
Auxiliary
DCC - Outer + Inner
DCC - Inner
68 A
50 A
80 + 41
41
1,65
1,00
3,30
0,90
125 g/h
71 g/h
236 g/h
64 g/h
0,35
0,30
1,90
0,30
25 37 45
Type of gas used Model conguration
4 BURNERS
Rated thermal
owrate (kW)
Total rated
consumption
Air required (m3) for
burning 1m3 of gas
G20 20 mbar 2 SR - 1 AUX - 1DCC 8,00 781 l/h 9,52
G30 28-30 mbar 2 SR - 1 AUX - 1DCC 7,6 0 567 g/h 30,94
G31 37 mbar 2 SR - 1 AUX - 1DCC 7,6 0 557 g/h 23,80
ELECTRIC SUPPLY: 220-240 V ~ 50-60 Hz - 0,6W
Loading ...
Loading ...
Loading ...