Controller - Operator Settings
20
With the Oven in Stand-ByMode (i.e. Power to oven but both displays are blank).
1. ENTERING THE OPERATOR SETTING MODE.
Press and hold 'Steam' and Timer-Start/Stopkeys together for 3 seconds.
Upper Display will show .
Lower Display will flash .
2. SETTING PASSWORD (OPERATOR PASSWORD - 123).
Rotate Timerknob to set password .
Press Fan Lokey to confirm password.
Upper Display will show one of the setting codes, eg.
Lower Display will show the value of the setting, eg.
3. CHANGING THE OPERATOR SETTINGS.
Rotate Timerknob to the setting required.
Press Fan Lokey to confirm setting required. Lower Display will flash.
While Lower Display is flashing, rotate Timerknob to select value required.
Press Fan Lokey to confirm value. Lower Display will stop flashing.
4. EXITING THE OPERATOR SETTING MODE.
Press On-Off/Lightkey, to return to Stand-By Mode.
Oven Pre-Heat; - (Automatic Pre-Heat Temp on oven start-up).
60 - 260°C
140 - 500°F.
150ºC
(302ºF)
Alarm Volume - Can be adjusted to suit operators preference.
0 - 10. 5
Program Pre-Heating Condition - This setting allow s for pre-heating Readytemperature in
Program ModeMode to be set higher than Program Set Temperature. Factory Default setting is
‘0’ (Equal to Program Setting).
0 - 30°C
0 - 54°F.
0
Light Auto OffSetting Time - (E32 from Ser. No. 759469).
0 = ‘On/Off’.
1 = 1 minute auto Off’.
2 = 2 minutes auto Off’, etc.
0 - 60 mins. 0
Multi-Stage Enable - (E32 from Ser. No. 759469).
This setting enables multi-stage programming. Factory default is YES’, multi-stage programming is
enabled. Setting this to nosimplifies programming and program cooking.
YESor no’. YES
Enable Steam Injection.
0 = No Steam.
1 = Bake Steam.
2 = Moisture Mode.
2 Yes