Troubleshooting
3. The units should start blinking red one minutes after turning on the AC circuit breaker.
Then blue led blinking. This means they are producing power normally, the faster
blinking of the blue led means more power generated.
4. Configure the internal wifi module according to its user manual.
5. The Microinverters will start to send performance data over wifi module to the network
every 5 minutes.It enables customers to monitor performance data of each microinverter
through website and APP.
Qualified personnel can use the following troubleshooting steps if the PV system does
not operate correctly:
NOTE: When AC power is applied but the microinverter not started up, about 0.1A current
and 25VA(W) power for each microinverter may be measured by a power meter. This
power is reactive power,not consume from utility grid.
Start up LED
Operation LED
One minute after DC power is first applied to the microinverter,one
short red blinks indicate a successful microinverter startup sequence,
be equal or greater than two short red blinks after DC power is first
applied to the microinverter indicate a failure during microinverter
setup.
Flashing Slow Blue - Producing small power
Flashing Fast Blue - Producing big power
Flashing Red - Not producing power
Red blinking two times - AC low-voltage or high-voltage
Red blinking three times - Grid failure
Status Indications and Error Reporting