SYMPTOMS PROBABLE CAUSE REMEDY
Troubleshooting Ventura Remote Manual Systems
PPM High
TDS meter needs calibraon
Feed Flow or Clark Pump
Problem
Membrane fouled or dam-
aged
Fouled Prelters
Recalibrate TDS meter or taste test water
unl it can be replaced
Low product ow, recovery percentage, or
feed pressure can lead to drop in product
water quality. Perform Flow Test &
address ow issue.
Clean membrane or consult dealer about
membrane damage.
If system ow (product plus brine) is to
specicaon, the membrane is clean, the
product ows are consistent with the
system ow, and the water quality is sll
not acceptable, then replacement of the
membrane is indicated. By design, high
ppm typically has to do with something
other than the membrane itself.
Freshwater ush procedure needs to be
tested and adjusted. PPM of brine
discharge must be below 1000ppm at end
of ush cycle.
Replace lters or run watermaker for an
extended period of me with pressure
relief valve open to rinse.