Components
Sea Strainer Mount close to the intake through-hull, in a
locaon that can handle water spillage during service.
5 Micron Prelter Bowl Locate in an area that allows easy
access as this will be the most frequently serviced module while
cruising. Mount vercally and leave room below bowl for lter
changes.
Do not mount above water-sensitive equipment.
CAUTION
!
Feed Pump Module
Mount the feed pump module on a vercal surface, no more
than 3-feet (1.0M) above the waterline. It is preferable to
mount as low as possible. Locate in an area that allows easy
access to the charcoal lter, and the service valve. Keep
future maintenance in mind when choosing a locaon, and do
not mount above water-sensive equipment.
NOTE: IF INSTALLING THE Z±ION, SEE Z±ION
INSTALLATION INSTRUCTIONS FOR MORE DETAILS.