Setting the Hot Air Auto/Manual Operation
This Power-Station is equiped with a user selectable auto/manual operation mode.
In the auto mode, the system will detect ( through magnetic switch) when the hot
air gun is placed in the cradle and automatically start the cool down procedure.
However, if the user wants to disable this feature, then apply the following steps to
switch between auto and manual. Factory default for this unit is “auto” While in the
auto mode, once the end user removes the hot air gun from the cradle, the system
will quickly return to the setting it was on when the hot air gun was originally
placed in the handle. In order to switch between auto mode and manual mode,
follow this procedure:
Press and hold BOTH UP and DOWN arrow buttons on the HOT AIR
switch panel. After 4 seconds the AUTO or MANUAL indicator on the
panel will flash and buttons should then be released
Now select AUTO mode by pressing the UP button on the hot air switch
panel or select MANUAL mode by pressing the DOWN button on the hot
air switch panel
After 5 seconds, the AUTO or MANUAL indicators will stop flashing and the
selected mode will be stored in memory
Setting the soldering iron sleep mode
The soldering iron features automatic sleep mode operation which may be disabled
or adjusted to any desired operating time from 1 to 99 minutes. This feature may be
set by the end user using the following procedure:
PRESS and HOLD BOTH the UP and DOWN arrow buttons on the
SOLDERING switch panel. After 4 seconds, the SLEEP indicator on the
display will flash and when this occurs, the buttons should be released. The
present sleep time setting will be displayed above the SLEEP indicator.
Now the desired sleep time may be reset by pressing the UP or DOWN buttons
on the soldering panel. A value of “0” will effectiovely disable the auto sleep
feature.
After 5 seconds, the SLEEP indicators will stop flashing and the selected auto sleep
time will be stored in the memory.