Door and Hinge Removal
Some installations require door removal to get
refrigerator to final location.
To avoid severe personal injury or death,
observe the following:
Disconnect power to refrigerator before removing
doors. Connect power only after replacing doors.
Green ground wire must be attached to top hinge
while performing door removal and replacement.
Tape decorative panels (select models) securely
into place before removing door handles.
To avoid property damage, observe the following:
Protect vinyl or other flooring with cardboard, rugs
or other protective material, prior to moving
refrigerator.
1. Unplug power cord from power source.
2. Remove toe grille and bottom bracket covers (see
page 8).
Open both doors 180°, or as wide as possible.
Note
For refrigerators in operation, shut off water before
removing water line from the door.
If tube end is damaged, cut off 5/8"before
reconnecting.
If leaking occurs, disconnect and reconnect the
line.
3. Close doors.
/4. Remove top hinge covers by
removing Phillips screws.
5. Unscrew 5/,8"hex head screws
from top hinges.
Do not remove screw
connecting green ground
wire.
6. Detach main wire connector harness and red wire
harness.
To detach main wire
harness, use a flat blade
tool or fingernail to press
junction point between two
connectors to release.
To detach red wire harness,
press tab on underside of
connector to release.
7. Remove top hinges along with doors.
To Disconnect the Water Line:
Push in white collar (A) and hold.
Pull the door-side tube from the connector (B).
To Reconnect the Water Line:
Firmly push tube 8/;, into the connector. Use
lines on the tube as a guide for full insertion.
8. Remove bottom hinges with a _/8"hex head driver.