• Turn the LUX knob clockwise on the maximum (sun). Turn the SENS knob clockwise on
the maximum (+). Turn the TIME knob anti-clockwise on the minimum (10s).
• When you switch on the power, the light will be on at once. And 10sec±3sec later the
light will be o automatically. Then if the sensor receives induction signal again, it can
work normally.
• When the sensor receives the second induction signals within the first induction, it will
restart to time from the moment.
• Turn LUX knob anti-clockwise on the minimum (3). If the ambient light is less than 3LUX
(darkness), the inductor load could work when it receives induction signal.
CONNECTION-WIRE DIAGRAM
TEST
Note: When testing in daylight, please turn LUX knob to ☼ (SUN) position, otherwise the
sensor could not work!